Version 2025R1 Release Notes

Release 1 (June 2025)


New Features
Fixed Bugs
Changes
  • File - Remove Export Graphics action

    The legacy Export Graphics action has been removed from the File menu. Adding graphics to a template should be used instead.

  • Blob - Switch blob calculations to use the IEEE-754 basic operations

    Blob calculations have been switched to use the Apache Commons Math's FastMath library that relies only on IEEE-754 basic operations for better future compatibility.

    This change may result in small variations to the following calculated attributes:

    • Skewness I/II
    • Kurtosis I/II
    • Weight A/B(x,y)
    • Shape A/B(x,y)
    • IPeak Value I/II
    • Resolution 2D
    • Orientation

  • I/O - Remove outdated XML header

    The XML header for .gci files, templates, and various other XML formats, which was outdated, has been updated.

  • NIST - Removed NIST startup check dialog

    The NIST startup check dialog has been removed. Instead, the check is silently performed on launch and when attempting to run library search.

  • Configuration - Better default settings for Library Search

    The following default settings for Library Search (Configure > Settings > Search Library) have been changed:

    • Type of Spectrum: Blob/Area MS → Peak MS
    • Hitlist Size: 10 → 25
    • Apply post-search constraints when selecting the top hit: disabled → enabled
    • Match Factor Threshold: 0 → 600
    • Reverse Match Factor Threshold: 0 → 600

  • Configuration - Better default settings for Template Matching

    The following default settings for Template Matching have been changed:

    • Match Factor Spectral Constraint: disabled → enabled
    • Reverse Match Factor Spectral Constraint: disabled → enabled

  • Investigator - Class Label column is now Class

    In Investigator, the "Class Label" column is now named "Class".

  • Investigator - Limit Inspect Compounds right click action to 10 tabs at a time

    The Inspect Compounds right-click action in Investigator - Find Compounds is now limited to opening 10 tabs at a time.

  • Investigator - Peak and Area compound views maintain independent UI persistence

    Peak and Area compound views in Investigator now maintain independent persistence of various UI elements.

  • Investigator - PCA tab removed from Attribute view

    The PCA tab is no longer shown in the Attribute view. Instead, the PCA plot is available from the Run PCA toolbar button or the Run PCA button in the Attributes view.

  • Investigator - Auto Feature workflow now uses current library search and most other settings when Use Configuration is turned off.

    The Auto Feature workflow previously ignored some of the current settings when Use Configuration was turned off. These settings now use the currently configured value. The affected settings included the following:

    • The Perform library search after 'blob detection' automatically setting was treated as disabled.
    • The Filter Type setting for Baseline Correction was treated as Legacy.
    • The Iterations setting for gradient Baseline Correction was treated as 2-step.
    • The Spectral Constraints for Template Matching were treated as disabled for the Cumulative Image and Feature Template steps. However, the currently configured setting was used for the Match Template step.
    • Many of the Search Library settings were ignored and used the legacy default settings when performing library search using the Enhanced with Library Search Extraction Method in the Auto Feature workflow.

    The following setting is still used regardless of the current configuration:

    • The Detection Type setting for Blob Detection is treated as 2D